Biological Safety Cabinet TRBC-602

Biological Safety Cabinet TRBC-602

Biological Safety Cabinet TRBC-602 Is a closed working environment that can effectively protect against corrosion caused by corrosive substances and disinfectants. Digital display panels are used in all steel-framed workplaces. This includes UV lamps, fluorescent lights, and differential displays. There are HEPA filters and primary filters. HEPA filters contribute to a clean working environment. It is a sterilization method linked with safety functions. Discharges 100% of the airflow outside the cross-contamination.

Qty:

$1640

Specifications

Number Of Colonies ≤0.5pcs/dish hour (Φ90mm culture plate)
Average Wind Speed 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
Front Suction Wind Speed 0.55m ± 0.025m/s (30% Efflux)
Noise ≤65 dB(A)
Vibration Half Peak ≤3 μm
Voltage AC single-phase, 220 V/50 Hz
Maximum Power Consumption 600 W
Weight 250 Kg
Working Area W1×D1×H1 1340×650×620 mm
Overall Dimension W×D×H 1500×800×2100 mm
High-Efficiency Filter Specification And Quantity 1280×490×50×1, 820×380×70×1
Specification And Quantity Of Fluorescent Lamp/Ultraviolet Lamp 30W×2/30W×1

Features

  • It is built with air curtain isolation in mindBy discharging 100% of the airflow outside, negative pressure vertical laminar flow, no need to install pipes
  • It prevents internal and external cross-contamination
  • The glass door can be moved up and down, and it can be positioned in any direction
  • It is simple to use and can be sterilized completely closed
  • W0ith the prompting of the positioning height, limit alarm
  • The work area's power output socket is equipped with a waterproof socket and a sewage interface for the operator's convenience
  • A special filter installed at the exhaustion of air to control pollution emissions
  • The working environment is made of high-quality stainless steel that is smooth, seamless, and corrosion-resistant
  • It can be disinfected quickly and thoroughly, and it can resist corrosion from corrosive agents and disinfectants
  • An LED LCD panel controls it
  • Built-in UV lamp protection device, which can only turn on when the safety door is shutdown
  • With a DOP detection port and a built-in differential pressure gauge, that tilts 10˚ by the human body design concept

Customer Testimonials

Biological Safety Cabinet : Biological Safety Cabinet TRBC-601

Biological Safety Cabinet TRBC-601

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
  • Noise : ≤65 dB(A)
$1657
Biological Safety Cabinet : Biological Safety Cabinet TRBC-603

Biological Safety Cabinet TRBC-603

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
  • Noise : ≤65 dB(A)
$1260
Biological Safety Cabinet : Biological safety cabinet TRBC-604
Biological safety cabinet TRBC-604
  • The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
  • The Average Wind Speed- Middle : 0.26 + -0.025 m/S
  • The Average Wind Speed-Inside : 0.35 + -0.025 m/s
  • Air Tightness : <=10 – 6 m/S 500 Pa leakage rate
$1175
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-601

Vertical Air Laminar Flow Cabinet TRVLC-601

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1507
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-602

Vertical Air Laminar Flow Cabinet TRVLC-602

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1378
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-603

Vertical Air Laminar Flow Cabinet TRVLC-603

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1617
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-604
Vertical Air Laminar Flow Cabinet TRVLC-604
  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1319
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-605
Vertical Air Laminar Flow Cabinet TRVLC-605
  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1516
Vertical Air Laminar Flow Cabinet : Vertical Air Laminar Flow Cabinet TRVLC-606

Vertical Air Laminar Flow Cabinet TRVLC-606

  • The Average Wind Speed : 0.25 to 0.45m/s
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • Illumination : ≥300LX
$1933
Horizontal Laminar Flow Cabinet : Horizontal Laminar flow cabinet TRHL-603

Horizontal Laminar flow cabinet TRHL-603

  • Cleanliness Level : Class 100 @ ≥ 0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
  • Noise : ≤62dB (A)
$1174
Horizontal Laminar Flow Cabinet : Horizontal Laminar flow cabinet TRHL-604
Horizontal Laminar flow cabinet TRHL-604
  • Cleanliness Level : Class 100 @ ≥ 0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
  • Noise : ≤62dB (A)
$1194
Horizontal Laminar Flow Cabinet : Horizontal Laminar flow cabinet TRHL-601
Horizontal Laminar flow cabinet TRHL-601
  • Cleanliness Level : Class 100@≥0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
  • Noise : ≤62dB(A)
$1089
Horizontal Laminar Flow Cabinet : Horizontal Laminar flow cabinet TRHL-602

Horizontal Laminar flow cabinet TRHL-602

  • Cleanliness Level : Class 100@≥0.5μM
  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
  • Noise : ≤62dB(A)
$1876
Vertical and Horizontal Laminar Flow Cabinet : Vertical and Horizontal Laminar Flow Cabinet TRVHC-602

Vertical and Horizontal Laminar Flow Cabinet TRVHC-602

  • The Average Wind Speed : 0.25 to 0.45m/s (Speed two-speed)
  • Noise : ≤62 dB
  • Power Supply : AC, 220 V/50Hz
  • MaximumPower Consumption : 800 W
$1812
Vertical and Horizontal Laminar Flow Cabinet : Vertical and Horizontal Laminar Flow Cabinet TRVHC-601
Vertical and Horizontal Laminar Flow Cabinet TRVHC-601
  • The Average Wind Speed : 0.25 to 0.45m/s(Speed two-speed)
  • Noise : ≤62dB
  • Power Supply : AC, 220 V/50Hz
  • MaximumPower Consumption : 300W
$1757